HT Power Cables 3C-150SQMM 11/11KV Earthed Armoured

SKU: 10001.10000022.20002 Category:

Login to view prices

Weight 1.71 kg
Brand

Avocab

MOC of conductor

Aluminium

No of cores (NOS)

3

Size - main (sqmm)

150

Voltage - Earthed (KV)

11/11

Earthed

Yes

Armoured

Yes

Cable type/code

A2XFY

MOC of insulation

XLPE

MOC of inner sheath

PVC

MOC of outer sheath

PVC

Testing Voltage (V)

11 KV for 5 minutes

Max DC resistance (Ω)

0.206

Max AC resistance (Ω)

0.264

Apr. inductance (mH/Km)

0.863

Apr. reactance (Ω/KM)

0.271

Apr. capacitance (μf/km)

0.093

Shrt-circuit rating(KA/sec)

14.2

Current rating - Duct (A)

209

Current - In ground(A)

242

Current rating - Air (A)

288

Form of conductor

Stranded

Shape of the conductor

Circular

No of strands - main (#)

37

Dia of strand - main (mm)

2.27

Dia of conductor-main(mm)

15.89

Thk of insulation-main(mm)

5.5

Thk of inner sheath (mm)

0.7

Armour dimensions(W x T mm)

6.1 x 1.4

Type of armouring

Galvanized flat strip

Thk of outer sheath (mm)

3

Apr. OD of cable (mm)

81

Weight of the cable (kg/km)

5508

Thk of conductor Screen(mm)

0.3

Thk - insulation screen(mm)

0.3

Thk of metallic screen(mm)

0.04

Reviews

There are no reviews yet.

Be the first to review “HT Power Cables 3C-150SQMM 11/11KV Earthed Armoured”

Your email address will not be published. Required fields are marked *

Weight 1.71 kg
Brand

Avocab

MOC of conductor

Aluminium

No of cores (NOS)

3

Size - main (sqmm)

150

Voltage - Earthed (KV)

11/11

Earthed

Yes

Armoured

Yes

Cable type/code

A2XFY

MOC of insulation

XLPE

MOC of inner sheath

PVC

MOC of outer sheath

PVC

Testing Voltage (V)

11 KV for 5 minutes

Max DC resistance (Ω)

0.206

Max AC resistance (Ω)

0.264

Apr. inductance (mH/Km)

0.863

Apr. reactance (Ω/KM)

0.271

Apr. capacitance (μf/km)

0.093

Shrt-circuit rating(KA/sec)

14.2

Current rating - Duct (A)

209

Current - In ground(A)

242

Current rating - Air (A)

288

Form of conductor

Stranded

Shape of the conductor

Circular

No of strands - main (#)

37

Dia of strand - main (mm)

2.27

Dia of conductor-main(mm)

15.89

Thk of insulation-main(mm)

5.5

Thk of inner sheath (mm)

0.7

Armour dimensions(W x T mm)

6.1 x 1.4

Type of armouring

Galvanized flat strip

Thk of outer sheath (mm)

3

Apr. OD of cable (mm)

81

Weight of the cable (kg/km)

5508

Thk of conductor Screen(mm)

0.3

Thk - insulation screen(mm)

0.3

Thk of metallic screen(mm)

0.04

Reviews

There are no reviews yet.

Be the first to review “HT Power Cables 3C-150SQMM 11/11KV Earthed Armoured”

Your email address will not be published. Required fields are marked *